MO2: Absorbers not so good and absorbers to have a closer look =============================================================== s060_01_m02c02: thicknesses at obtuse as if it had been cured in mould 03 or 04 instead of 01. In principle OK. At UAM. b0160_02_m02c02: 2 half-waves with large "measured" thickness at acute. Height of folds different than other absorbers at obtuse. Probably OK but check before mounitng. At UAM. b0282_07_m02c02: Watch the many hits area indicated in QCS. Measurements OK. In principle OK. At UAM. b0157_08_m02c02: problems at acute side of front bar. Watch it carefully before using. Measurements OK. At UAM. b0133_06_m02c09: parallel straight lines marked deeply on the absorber reported on the QCS. Check carefully. Measurements OK. At UAM.